355 research outputs found

    Range imager performance comparison in homodyne and heterodyne operating modes

    Get PDF
    Range imaging cameras measure depth simultaneously for every pixel in a given field of view. In most implementations the basic operating principles are the same. A scene is illuminated with an intensity modulated light source and the reflected signal is sampled using a gain-modulated imager. Previously we presented a unique heterodyne range imaging system that employed a bulky and power hungry image intensifier as the high speed gain-modulation mechanism. In this paper we present a new range imager using an internally modulated image sensor that is designed to operate in heterodyne mode, but can also operate in homodyne mode. We discuss homodyne and heterodyne range imaging, and the merits of the various types of hardware used to implement these systems. Following this we describe in detail the hardware and firmware components of our new ranger. We experimentally compare the two operating modes and demonstrate that heterodyne operation is less sensitive to some of the limitations suffered in homodyne mode, resulting in better linearity and ranging precision characteristics. We conclude by showing various qualitative examples that demonstrate the system’s three-dimensional measurement performance

    Shape and deformation measurement using heterodyne range imaging technology

    Get PDF
    Range imaging is emerging as a promising alternative technology for applications that require non-contact visual inspection of object deformation and shape. Previously, we presented a solid-state full-field heterodyne range imaging device capable of capturing three-dimensional images with sub-millimetre range resolution. Using a heterodyne indirect time-of-flight configuration, this system simultaneously measures distance (and intensity), for each pixel in a cameras field of view. In this paper we briefly describe our range imaging system, and its principle of operation. By performing measurements on several metal objects, we demonstrate the potential capabilities of this technology for surface profiling and deformation measurement. In addition to verifying system performance, the reported examples highlight some important system limitations. With these in mind we subsequently discuss the further developments required to enable the use of this device as a robust and practical tool in non-destructive testing and measurement applications

    A power-saving modulation technique for time-of-flight range imaging sensors

    Get PDF
    Time-of-flight range imaging cameras measure distance and intensity simultaneously for every pixel in an image. With the continued advancement of the technology, a wide variety of new depth sensing applications are emerging; however a number of these potential applications have stringent electrical power constraints that are difficult to meet with the current state-of-the-art systems. Sensor gain modulation contributes a significant proportion of the total image sensor power consumption, and as higher spatial resolution range image sensors operating at higher modulation frequencies (to achieve better measurement precision) are developed, this proportion is likely to increase. The authors have developed a new sensor modulation technique using resonant circuit concepts that is more power efficient than the standard mode of operation. With a proof of principle system, a 93–96% reduction in modulation drive power was demonstrated across a range of modulation frequencies from 1–11 MHz. Finally, an evaluation of the range imaging performance revealed an improvement in measurement linearity in the resonant configuration due primarily to the more sinusoidal shape of the resonant electrical waveforms, while the average precision values were comparable between the standard and resonant operating modes

    Heterodyne range imaging as an alternative to photogrammetry

    Get PDF
    Solid-state full-field range imaging technology, capable of determining the distance to objects in a scene simultaneously for every pixel in an image, has recently achieved sub-millimeter distance measurement precision. With this level of precision, it is becoming practical to use this technology for high precision three-dimensional metrology applications. Compared to photogrammetry, range imaging has the advantages of requiring only one viewing angle, a relatively short measurement time, and simplistic fast data processing. In this paper we fist review the range imaging technology, then describe an experiment comparing both photogrammetric and range imaging measurements of a calibration block with attached retro-reflective targets. The results show that the range imaging approach exhibits errors of approximately 0.5 mm in-plane and almost 5 mm out-of-plane; however, these errors appear to be mostly systematic. We then proceed to examine the physical nature and characteristics of the image ranging technology and discuss the possible causes of these systematic errors. Also discussed is the potential for further system characterization and calibration to compensate for the range determination and other errors, which could possibly lead to three-dimensional measurement precision approaching that of photogrammetry

    The Waikato range imager

    Get PDF
    We are developing a high precision simultaneous full-field acquisition range imager. This device measures range with sub millimetre precision in range simultaneously over a full-field view of the scene. Laser diodes are used to illuminate the scene with amplitude modulation with a frequency of 10MHz up to 100 MHz. The received light is interrupted by a high speed shutter operating in a heterodyne configuration thus producing a low-frequency signal which is sampled with a digital camera. By detecting the phase of the signal at each pixel the range to the scene is determined. We show 3D reconstructions of some viewed objects to demonstrate the capabilities of the ranger

    Video-rate or high-precision: A flexible range imaging camera

    Get PDF
    A range imaging camera produces an output similar to a digital photograph, but every pixel in the image contains distance information as well as intensity. This is useful for measuring the shape, size and location of objects in a scene, hence is well suited to certain machine vision applications. Previously we demonstrated a heterodyne range imaging system operating in a relatively high resolution (512-by-512) pixels and high precision (0.4 mm best case) configuration, but with a slow measurement rate (one every 10 s). Although this high precision range imaging is useful for some applications, the low acquisition speed is limiting in many situations. The system’s frame rate and length of acquisition is fully configurable in software, which means the measurement rate can be increased by compromising precision and image resolution. In this paper we demonstrate the flexibility of our range imaging system by showing examples of high precision ranging at slow acquisition speeds and video-rate ranging with reduced ranging precision and image resolution. We also show that the heterodyne approach and the use of more than four samples per beat cycle provides better linearity than the traditional homodyne quadrature detection approach. Finally, we comment on practical issues of frame rate and beat signal frequency selection

    Putting Quality Functional Assessment into Practice in Schools: A Research Agenda on Behalf of E/BD Students

    Get PDF
    The discipline provisions of the IDEA place emphasis on gaining an understanding of why the student is motivated to engage in problem behavior and to consider, when appropriate, positive behavioral interventions, strategies, and supports to address the behavior. These legislative mandates bring center stage a range of new duties and responsibilities for the IEP team. This article discusses the problems that school divisions across the country are encountering when implementing these requirements and recommends a course of research to address these issues

    Acute kidney injury in Ugandan children with severe malaria is associated with long-term behavioral problems

    Get PDF
    Background Acute kidney injury (AKI) is a risk factor for neurocognitive impairment in severe malaria (SM), but the impact of AKI on long-term behavioral outcomes following SM is unknown. Methods We conducted a prospective study on behavioral outcomes of Ugandan children 1.5 to 12 years of age with two forms of severe malaria, cerebral malaria (CM, n = 226) or severe malarial anemia (SMA, n = 214), and healthy community children (CC, n = 173). AKI was defined as a 50% increase in creatinine from estimated baseline. Behavior and executive function were assessed at baseline and 6, 12, and 24 months later using the Child Behavior Checklist and Behavior Rating Inventory of Executive Function, respectively. Age-adjusted z-scores were computed for each domain based on CC scores. The association between AKI and behavioral outcomes was evaluated across all time points using linear mixed effect models, adjusting for sociodemographic variables and disease severity. Results AKI was present in 33.2% of children with CM or SMA at baseline. Children ≥6 years of age with CM or SMA who had AKI on admission had worse scores in socio-emotional function in externalizing behaviors (Beta (95% CI), 0.52 (0.20, 0.85), p = 0.001), global executive function (0.48 (0.15, 0.82), p = 0.005) and behavioral regulation (0.66 (0.32, 1.01), p = 0.0002) than children without AKI. There were no behavioral differences associated with AKI in children <6 years of age. Conclusions AKI is associated with long-term behavioral problems in children ≥6 years of age with CM or SMA, irrespective of age at study enrollment

    Clinical setting influences off-label and unlicensed prescribing in a paediatric teaching hospital

    Get PDF
    Purpose - To estimate the prevalence of off-label and unlicensed prescribing during 2008 at a major paediatric teaching hospital in Western Australia. Methods - A 12-month retrospective study was conducted at Princess Margaret Hospital using medication chart records randomly selected from 145,550 patient encounters from the Emergency Department, Inpatient Wards and Outpatient Clinics. Patient and prescribing data were collected. Drugs were classified as off-label or unlicensed based on Australian registration data. A hierarchical system of age, indication, route of administration and dosage was used. Drugs were classified according to the Anatomical Therapeutic Chemical Code. Results - A total of 1,037 paediatric patients were selected where 2,654 prescriptions for 330 different drugs were prescribed to 699 patients (67.4%). Most off-label drugs (n = 295; 43.3%) were from the nervous system; a majority of unlicensed drugs were systemic hormonal preparations excluding sex hormones (n = 22, 32.4%). Inpatients were prescribed more off-label drugs than outpatients or Emergency Department patients (p < 0.0001). Most off-label prescribing occurred in infants and children (31.7% and 35.9% respectively) and the highest percentage of unlicensed prescribing (7.2%) occurred in infants (p < 0.0001). There were 25.7% of off-label and 2.6% of unlicensed medications prescribed across all three settings. Common reasons for off-label prescribing were dosage (47.4%) and age (43.2%). Conclusion - This study confirmed off-label and unlicensed use of drugs remains common. Further, that prevalence of both is influenced by the clinical setting, which has implications in regards to medication misadventure, and the need to have systems in place to minimise medication errors. Further, there remains a need for changes in the regulatory system in Australia to ensure that manufacturers incorporate, as it becomes available, evidence regarding efficacy and safety of their drugs in children in the official product information

    Rapid Pharmacokinetic and Biodistribution Studies Using Cholorotoxin-Conjugated Iron Oxide Nanoparticles: A Novel Non-Radioactive Method

    Get PDF
    Recent advances in nanotechnology have led to the development of biocompatible nanoparticles for in vivo molecular imaging and targeted therapy. Many nanoparticles have undesirable tissue distribution or unacceptably low serum half-lives. Pharmacokinetic (PK) and biodistribution studies can help inform decisions determining particle size, coatings, or other features early in nanoparticle development. Unfortunately, these studies are rarely done in a timely fashion because many nanotechnology labs lack the resources and expertise to synthesize radioactive nanoparticles and evaluate them in mice.To address this problem, we developed an economical, radioactivity-free method for assessing serum half-life and tissue distribution of nanoparticles in mice. Iron oxide nanoparticles coated with chitosan and polyethylene glycol that utilize chlorotoxin as a targeting molecule have a serum half-life of 7-8 hours and the particles remain stable for extended periods of time in physiologic fluids and in vivo. Nanoparticles preferentially distribute to spleen and liver, presumably due to reticuloendothelial uptake. Other organs have very low levels of nanoparticles, which is ideal for imaging most cancers in the future. No acute toxicity was attributed to the nanoparticles.We report here a simple near-infrared fluorescence based methodology to assess PK properties of nanoparticles in order to integrate pharmacokinetic data into early nanoparticle design and synthesis. The nanoparticles tested demonstrate properties that are excellent for future clinical imaging strategies and potentially suitable for targeted therapy
    corecore